Medical Ventilators for Sale

Aimix supplies medical ventilators, a key device that is usually used for ICU nursing work. Due to the fast spreading of the infectious virus right now, the need for the medical ventilators is very high at this particular time. Therefore, Aimix designs and supplies two kinds of ventilators to fight against the virus, and they are Y-25T and Y-30T ventilators. Medical ventilator is a breathing machine to help patient infected by the virus to auxiliary breaths.

medical equipment
Medical Ventilators for Sale in Aimix

Click here for Price

Breathing Machine-Medical Ventilator for Sale in Aimix Group

Aimix has a huge quantities of ventilators in stock which are sufficient to supply for the use in the USA, Philippines, England, Spanish, South Africa, Germany and all over the world. The medical ventilator is mainly used for the nursing care for the critically ill patients infected by the virus. Its working principle is to provide breathable air to the lungs and help the patients breath. Contact us for getting more details and price on our ventilators now.

Click here for Price

Parameters of Aimix Y-25T Medical Ventilator Machine:

Model Y-25T
Ventilator type Ventilator type Electric control
Scope of application Treatment and titration of sleep apnea hypopnea syndrome, severe snoring, and respiratory insufficiency.
Display interface 3.5-inch LED screen, Chinese operating system
*Ventilation mode CPAP、S、S/T、T
Pressure range Pressure range 4-25cmH2O(±0.5cmH2O)
Pressure accuracy + 0.5cmH2O
Parameter setting Delayed boost 0-60min, set the division interval 5min
Initial pressure 4cmh2o treatment pressure / respiratory pressure setting
Therapeutic pressure 4-20cmh2o (in CPAP mode)
Target tidal volume 150ml – 1500ml, on / off
Maximum suction pressure 4-25cmh2o, (can be set when the target tidal volume function is on)
Maximum suction pressure 4-25cmh2o (not higher than the suction pressure), (can be set when the target tidal volume function is on)
Inspiratory phase pressure              4-25cmH2O
Expiratory pressure 4-25cmH2O
Expiratory decompression Patient, off, 1-3, three adjustable
Manual voltage regulation 0-2 gear, 0-2cmh2o (only available in CPAP mode)
Inspiratory sensitivity 1-8 stalls
Expiratory sensitivity 1-8 stalls
Respiratory frequency 3-40 times / min
Inspiratory time 0.3-3.0s
Backup rate On / off, default 10
Pressure rise time 1-4 stalls
Humidifier 1-5 adjustable in 5 gears
 

 

*Titration function

Support manual and automatic pressure titration, built-in remote wireless communication module, complete the random switching of single and double level modes in the titration process, and control more than 11 ventilator parameters at the same time.
Auxiliary function Automatic air leakage compensation, automatic startup, automatic shutdown, delayed shutdown, screen backlight adjustment
Monitoring parameters Pressure, tidal volume, respiratory rate, minute ventilation volume, air leakage volume, inspiratory time, blood oxygen saturation
Wavy curve Pressure time waveform, flow rate time waveform
Alarm prompt Pipeline and mask falling off, air leakage prompt, power interruption, treatment machine failure, humidifier failure, low voltage, high respiratory rate, low respiratory rate, low minute ventilation volume, low blood oxygen, replacement of filter cotton, full SD card, re insertion of SD card
*Data management Network data BMC + respiratory health management cloud platform
SD card data Resart NPAP data analysis software
Parts SD card Standard
SD card slot Standard
Piping φ 22mm, 1.8m long
Face shield F2 nose mask as standard
Noise Less than 30dB
Environment condition When used During transportation and storage
Temperature 5 -35 C -20 C -55 C
Atmospheric pressure 760-1060hPa 760-1060hPa
Working hours More than 8 hours
Power supply requirements AC voltage 100-240V
Frequency 50Hz/60Hz
Input power Less than 2A
Waterproof level IP22 – drip proof equipment
Instrument size 290mm×180mm×134mm
Weight 1.5kg (excluding humidifier) 2.5kg (including humidifier)

Click here for Price

Parameters of Aimix Y-30T Medical Ventilator Machine:

Model Y-30T
Ventilator type Ventilator type Electric control
Scope of application Treatment and titration of sleep apnea hypopnea syndrome, severe snoring, and respiratory insufficiency.
Display interface 3.5-inch LED screen, Chinese operating system
*Ventilation mode CPAP、S、S/T、T
Pressure range Pressure range 4-30cmH2O(±0.5cmH2O)
Pressure accuracy + 0.5cmH2O
Parameter setting Delayed boost 0-60min, set the division interval 5min
Initial pressure 4cmh2o treatment pressure / respiratory pressure setting
Therapeutic pressure 4-20cmh2o (in CPAP mode)
Target tidal volume 150ml – 1500ml, on / off
Maximum suction pressure 4-30cmh2o, (can be set when the target tidal volume function is on)
Maximum suction pressure 4-30cmh2o (not higher than the suction pressure), (can be set when the target tidal volume function is on)
Inspiratory phase pressure              4-30cmH2O
Expiratory pressure 4-30cmH2O
Expiratory decompression Patient, off, 1-3, three adjustable
Manual voltage regulation 0-2 gear, 0-2cmh2o (only available in CPAP mode)
Inspiratory sensitivity 1-8 stalls
Expiratory sensitivity 1-8 stalls
Respiratory frequency 3-40 times / min
Inspiratory time 0.3-3.0s
Backup rate On / off, default 10
Pressure rise time 1-4 stalls
Humidifier 1-5 adjustable in 5 gears
 

 

*Titration function

Support manual and automatic pressure titration, built-in remote wireless communication module, complete the random switching of single and double level modes in the titration process, and control more than 11 ventilator parameters at the same time.
Auxiliary function Automatic air leakage compensation, automatic startup, automatic shutdown, delayed shutdown, screen backlight adjustment
Monitoring parameters Pressure, tidal volume, respiratory rate, minute ventilation volume, air leakage volume, inspiratory time, blood oxygen saturation
Wavy curve Pressure time waveform, flow rate time waveform
Alarm prompt Pipeline and mask falling off, air leakage prompt, power interruption, treatment machine failure, humidifier failure, low voltage, high respiratory rate, low respiratory rate, low minute ventilation volume, low blood oxygen, replacement of filter cotton, full SD card, re insertion of SD card
*Data management Network data BMC + respiratory health management cloud platform
SD card data Resart NPAP data analysis software
Parts SD card Standard
SD card slot Standard
Piping φ 22mm, 1.8m long
Face shield F2 nose mask as standard
Noise Less than 30dB
Environment condition When used During transportation and storage
Temperature 5 -35 C -20 C -55 C
Atmospheric pressure 760-1060hPa 760-1060hPa
Working hours More than 8 hours
Power supply requirements AC voltage 100-240V
Frequency 50Hz/60Hz
Input power Less than 2A
Waterproof level IP22 – drip proof equipment
Instrument size 290mm×180mm×134mm
Weight 1.5kg (excluding humidifier) 2.5kg (including humidifier)

Click here for Price

    Please feel free to give your inquiry in the form below, we will reply in 24 hours.